A:
Softened water device can not be recycled
Possible reasons: 1, power system failure. 2, there are problems with the timer. 3, power interrupt.
Solution: 1, to ensure the integrity of the circuit, check the fuse, plug and switch. 2, reset timer. 3, re adjust the day of the time.
Have hard water
Possible reasons: 1, bypass valve open. 2, the lack of salt. 3, jet or filter plug. 4, the lack of water flow. 5, water supply pipe connection leak. 6, the internal valve leakage.
Solution: 1, close the bypass valve. 2, to the salt and salt from the water surface to maintain. 3, clear jet or filter. 4, check the injection time, if the flow control valve plug cleaning. 5, make sure that the water supply pipe is not broken, check the O ring and pipe joint. 6, replace the sealing ring, retainer and piston.
System with too much salt
Possible reasons: 1, salt is not correct. 2, the excessive water
Solution: 1, check the amount of salt and equipment. 2, look at the problem 7
Water pressure reduction
Possible reasons: water inlet and outlet pipes, control valve channels have foreign body
Solve the issue: cleaning the parts
Drain pipe resin
Possible reasons: 1. Air in the system. 2, overflow tank control valve installation is not correct.
Solution: 1, the system should have air discharge device. 2, check and adjust the correct overflow speed.
The excess of water
Possible reasons: 1, drainage flow control block. 2, the water system plug. 3, the timer does not cycle. 4, a foreign body in the salt liquid valve. 5, there is a foreign body in the salt flow control valve.
Solution: 1, clean. 2, cleaning water system and pipeline. 3, reset timer
. 4, clean the valve. 5, cleaning or replacement.
Water appeared in brine
Possible problems: 1, jet system blockage. 2, there is a foreign body in the suction valve. 3, the timer does not work. 4, suction flow control foreign body.
Solution: 1, cleaning or replacement. 2, clean or replace the suction valve. 3, the replacement of the timer. 4, cleaning or replacement.
Can not absorb salt
Possible reasons: 1, drainage flow control board plug. 2, jet jam. 3, jet filter net blockage. 4, the pipeline pressure is too low. 5, the controller internal leakage.
Solution: 1, cleaning drainage flow control board. 2, cleaning or replacement. 3, cleaning or replacement. 4, increase pressure. 5, replace the sealing ring, retainer and piston.
Controller loop
Possible cause: timer fault.
Solution: replace timer.
Drainage more than
Possible reasons: 1, the valve body. 2, the controller internal leakage. 3, the controller stuck salt absorption or backwashing. 4, stop or turn the timing motor. 5, equipment reduction in power outages.
Solution: 1, take the piston group to check and clear the foreign body, check different. Controller for regeneration stage. 2, replace the seal or piston. 3, replace the seal, retainer, piston. 4, the replacement of the timer. 5, re check the power supply.